Search
Now showing items 1-8 of 8
Fibres and Spheres
(Technische Universität Bergakademie Freiberg, 2019)
This repository includes the reconstructed TIFF-files from the following measurements:
LARGE (low-resolution) (due to filesize partioned in part I, II, III, IV and V)
1 large volume of particle mixture (50/50) of spheres ...
Different mixtures (by volume) of graphite-nanoparticles and analysis particles
(Technische Universität Bergakademie FreibergRalf Ditscherlein, TU Bergakademie Freiberg, Institut MVTAT, 2020)
To determine an optimal mixture of the two components, the following volume-fractions were analysed:
Nanoparticle:Particle
20vol-%:80vol-%
40vol-%:60vol-%
60vol-%:40vol-%
Tomographic dataset of a particulate Soda-lime glass sample
(Technische Universität Bergakademie Freiberg, 2021)
Soda-lime glass particle samples embedded in epoxy resin mixed with graphite nanoparticles as spacer and scanned with tomograph Zeiss Xradia Versa 510
Particle sample is segmented via a standard workflow in Fiji (ImageJ) ...
Tomographic dataset of a particulate Dolomite sample
(Technische Universität Bergakademie Freiberg, 2021)
Dolomite particle samples embedded in wax and scanned with tomograph Zeiss Xradia Versa 510
Particle sample is segmented via a standard workflow in Fiji (ImageJ) and provided as "segmented.zip"
Resulting discrete particles ...
Tomographic dataset of a particulate Al2O3 sample
(Technische Universität Bergakademie Freiberg, 2021)
Al2O3 particle samples embedded in wax and scanned with tomograph Zeiss Xradia Versa 510
Particle sample is segmented via a standard workflow in Fiji (ImageJ) and provided as "segmented.zip"
Resulting discrete particles ...
Tomographic dataset of a particulate Limstone sample
(Technische Universität Bergakademie Freiberg, 2021)
Limestone particle samples embedded in wax and scanned with tomograph Zeiss Xradia Versa 510.
Particle sample is segmented via a standard workflow in Fiji (ImageJ) and provided as "segmented.zip"
Resulting discrete ...
Tomographic dataset of a particulate Quartz sample
(Technische Universität Bergakademie Freiberg, 2021)
Quartz particle samples embedded in wax and scanned with tomograph Zeiss Xradia Versa 510
Particle sample is segmented via a standard workflow in Fiji (ImageJ) and provided as "segmented.zip"
Resulting discrete particles ...
Tomographic dataset of a particulate Mica sample
(Technische Universität Bergakademie Freiberg, 2021)
Mica particle samples embedded in wax and scanned with tomograph Zeiss Xradia Versa 510
Particle sample is segmented via a standard workflow in Fiji (ImageJ) and provided as "segmented.zip"
Resulting discrete particles ...