The OPARA service was recently upgraded to a new technical platform. You are visiting the outdated OPARA website. Please use https://opara.zih.tu-dresden.de/ for new data submissions. Previously stored data will be migrated in near future and then the old version of OPARA will finally be shut down. Existing DOIs for data publications remain valid.
Search
Now showing items 1-10 of 15
Benchmark analysis of synthetical images - source code and example DEM data
(Institut für GeotechnikTechnische Universität Dresden, 2018)
These files serve as the basis for a benchmark study on the image analysis to extract contact fabric from x-ray tomographies of granular materials.
They are based on the python package "spam": The Software for the Practical ...
Benchmark analysis of synthetical images - (updated) source code and example DEM data
(Technische Universität Dresden, 2019)
These files serve as the basis for a benchmark study on the image analysis to extract contact fabric from x-ray tomographies of granular materials. They are based on the python package "spam": The Software for the Practical ...
Tomographic dataset of a particulate Soda-lime glass sample
(Technische Universität Bergakademie Freiberg, 2021)
Soda-lime glass particle samples embedded in epoxy resin mixed with graphite nanoparticles as spacer and scanned with tomograph Zeiss Xradia Versa 510
Particle sample is segmented via a standard workflow in Fiji (ImageJ) ...
Tomographic dataset of a particulate Dolomite sample
(Technische Universität Bergakademie Freiberg, 2021)
Dolomite particle samples embedded in wax and scanned with tomograph Zeiss Xradia Versa 510
Particle sample is segmented via a standard workflow in Fiji (ImageJ) and provided as "segmented.zip"
Resulting discrete particles ...
Tomographic dataset of a particulate Al2O3 sample
(Technische Universität Bergakademie Freiberg, 2021)
Al2O3 particle samples embedded in wax and scanned with tomograph Zeiss Xradia Versa 510
Particle sample is segmented via a standard workflow in Fiji (ImageJ) and provided as "segmented.zip"
Resulting discrete particles ...
Tomographic dataset of a particulate Limstone sample
(Technische Universität Bergakademie Freiberg, 2021)
Limestone particle samples embedded in wax and scanned with tomograph Zeiss Xradia Versa 510.
Particle sample is segmented via a standard workflow in Fiji (ImageJ) and provided as "segmented.zip"
Resulting discrete ...
Tomographic dataset of a particulate Quartz sample
(Technische Universität Bergakademie Freiberg, 2021)
Quartz particle samples embedded in wax and scanned with tomograph Zeiss Xradia Versa 510
Particle sample is segmented via a standard workflow in Fiji (ImageJ) and provided as "segmented.zip"
Resulting discrete particles ...
Tomographic dataset of a particulate Mica sample
(Technische Universität Bergakademie Freiberg, 2021)
Mica particle samples embedded in wax and scanned with tomograph Zeiss Xradia Versa 510
Particle sample is segmented via a standard workflow in Fiji (ImageJ) and provided as "segmented.zip"
Resulting discrete particles ...
3 tomographic data sets of nano-CT measurements of a 30:70 vol-% mixture of talcum and saxolite
(Technische Universität Bergakademie Freiberg, 2022)
All 3 data sets are sub-volumes (Field of View approx. 65 µm) of a total sample of a particle mixture of talc and saxolite fixed in a matrix by means of epoxy resin and spacer particles (nanometre-sized carbon black ...
Computed tomography data of different resolution of expanded polypropylene foams of different density
(Technische Universität DresdenInstitute of Lightweight Engineering and Polymer Technology - ILK, 2022)
In this work, the morphology of three EPP bead foams with closed cells and different densities is studied using x-ray computed tomography. The specimens of 10 mm diameter and 10 mm length were cut from steam-chest-molded ...