Auflistung Mechanische Verfahrenstechnik nach Titel
Anzeige der Treffer 11-29 von 29
-
reconstructed CT data of filter cakes
(Technische Universität Bergakademie Freiberg, 2024)CT data of two filter cakes, built from glass beads (B70) and quartz sand (BCS201) in an in-situ pressure nutsch according german guideline VDI 2762-2. The soda-lime glass beads (density 2.55 g/cm³, 72.30 m.-% SiO2, 13.30 ... -
Supplementary information to the publication "Approaches to recycling of engine air filters"
(Technische Universität Bergakademie Freiberg, 2023)Dataset to the figures of the publication "Approaches to recycling of engine air filters" -
Supplementary information to the publication "Influence of the cell type on the physical processes of the mechanical recycling of automotive Lithium-Ion Batteries"
(Technische Universität Bergakademie Freiberg, 2023)This supplementary information contains 7 excel files with data, 3 pdf- and 1 pptx-file with photographs and 1 ZIP-folder "3D images" containing the obj-files of the 3D-images of the different cell types. The mtl- and the ... -
Supplementary information to the publication “Influence of different discharge levels on the mechanical recycling efficiency of lithium-ion batteries”
(Technische Universität Bergakademie Freiberg, 2024)Dataset to the publication “Influence of different discharge levels on the mechanical recycling efficiency of lithium-ion batteries” -
Supplementary information to the publication “Influence of the cell type on yield and composition of black mass deriving from a mechanical recycling process of automotive Lithium-Ion Batteries”
(Technische Universität Bergakademie Freiberg, 2023)This supplementary information contains 4 excel files with data. The content of the files is explained below: “1 - Cell composition and element content” contains the data behind Figures 2, 3 and 4 and additional element ... -
Supplementary information to the publication “Influence of the crusher settings and a thermal pre-treatment on the properties of the fine fraction (black mass) from mechanical Lithium-Ion Battery recycling”
(Technische Universität Bergakademie Freiberg, 2023)Dataset to the figures of the publication "Influence of the crusher settings and a thermal pre-treatment on the properties of the fine fraction (black mass) from mechanical Lithium-Ion Battery recycling" -
Supplementary material for the publication "Modelling the sorting of Lithium-Ion Battery components in a Zig-Zag air classifier"
(Technische Universität Bergakademie Freiberg, 2023)Data set for the publication "Modelling the sorting of Lithium-Ion Battery components in a Zig-Zag air classifier" -
Tomographic dataset of a particulate Al2O3 sample
(Technische Universität Bergakademie Freiberg, 2021)Al2O3 particle samples embedded in wax and scanned with tomograph Zeiss Xradia Versa 510 Particle sample is segmented via a standard workflow in Fiji (ImageJ) and provided as "segmented.zip" Resulting discrete particles ... -
Tomographic dataset of a particulate Dolomite sample
(Technische Universität Bergakademie Freiberg, 2021)Dolomite particle samples embedded in wax and scanned with tomograph Zeiss Xradia Versa 510 Particle sample is segmented via a standard workflow in Fiji (ImageJ) and provided as "segmented.zip" Resulting discrete particles ... -
Tomographic dataset of a particulate Limstone sample
(Technische Universität Bergakademie Freiberg, 2021)Limestone particle samples embedded in wax and scanned with tomograph Zeiss Xradia Versa 510. Particle sample is segmented via a standard workflow in Fiji (ImageJ) and provided as "segmented.zip" Resulting discrete ... -
Tomographic dataset of a particulate Mica sample
(Technische Universität Bergakademie Freiberg, 2021)Mica particle samples embedded in wax and scanned with tomograph Zeiss Xradia Versa 510 Particle sample is segmented via a standard workflow in Fiji (ImageJ) and provided as "segmented.zip" Resulting discrete particles ... -
Tomographic dataset of a particulate Quartz sample
(Technische Universität Bergakademie Freiberg, 2021)Quartz particle samples embedded in wax and scanned with tomograph Zeiss Xradia Versa 510 Particle sample is segmented via a standard workflow in Fiji (ImageJ) and provided as "segmented.zip" Resulting discrete particles ... -
Tomographic dataset of a particulate Soda-lime glass sample
(Technische Universität Bergakademie Freiberg, 2021)Soda-lime glass particle samples embedded in epoxy resin mixed with graphite nanoparticles as spacer and scanned with tomograph Zeiss Xradia Versa 510 Particle sample is segmented via a standard workflow in Fiji (ImageJ) ... -
X-ray micro-computed tomography scans of coated particles after mechano-fusion and process data for each experiment
(Technische Universität Bergakademie Freiberg, 2023)During the mechano-fusion experiments for particle coating available process data (time, rotational speed, temperature, power, torque) is recorded. Samples of alumina coated with polystyrene from three different experiments ... -
X-ray tomography scan of a cubical-shaped lithium aluminate slag particle (4 mm)
(Technische Universität Bergakademie Freiberg, 2023)X-ray tomography scans of a cubical-shaped lithium aluminate slag. This folder is split into the raw data TIFF before image processing, and the processed TIFF. The latter shows a binary stack containing only the microstructure ... -
X-ray tomography scan of partially dewatered filter cake
(Technical University Bergakademie Freiberg - Institute of Mechanical Process Engineering and Mineral Processing, 2021)X-ray tomography image of a partially dewatered filter cake. The initial slurry contains Al2O3 particles suspended in a potassium iodide-glycerol solution. These were separated by cake-forming filtration followed by ... -
X-ray tomography scan of partially dewatered filter cake
(Technical University Bergakademie Freiberg - Institute of Mechanical Process Engineering and Mineral Processing, 2021)X-ray tomography image of a partially dewatered filter cake. The initial slurry contains Al2O3 particles suspended in a potassium iodide-glycerol solution, which were separated by cake-forming filtration with subsequent ... -
X-ray tomography scans of filter cakes (feed slurry: variation in fraction of fines)
(Technical University Bergakademie Freiberg - Institute of Mechanical Process Engineering and Mineral Processing, 2021)X-ray tomography scans of partially dewatered filter cakes with variation of fine particles within the feed slurry. The mixture composition varies by addition of fines by 0, 20, 30, 40, 50, 60 and 100 vol.-%. The initial ... -
X-ray tomography scans of filter cakes (feed slurry: variation in solid volume fraction)
(Technical University Bergakademie Freiberg - Institute of Mechanical Process Engineering and Mineral Processing, 2021)X-ray tomography measurements (Zeiss X-radia Versa 510) of in-situ and in a VDI pressure nutsch built filter cakes (Al2O3 crushed particles in 25 mmol/l KI brine with 24 m.-% glycerol). The filter cakes are measured ...