3 tomographic data sets of nano-CT measurements of a 30:70 vol-% mixture of talcum and saxolite

datacite.FundingReference.funderName
datacite.FundingReference.funderName

Europäische Union

Contributing person
datacite.contributor.ProjectLeader

Ditscherlein, Ralf (orcid: 0000-0003-0233-4218)

Contributing person
datacite.contributor.Researcher

Hansen, Leonard

Contributing person
datacite.contributor.Researcher

Kirstein, Tom

Contributing person
datacite.contributor.Researcher

Englisch, Silvan

Contributing person
datacite.contributor.Researcher

Furat, Orkun

Contributing person
datacite.contributor.RightsHolder

FAU Erlangen-Nürnberg

Contributing person
datacite.contributor.RightsHolder

Universität Ulm

datacite.description.TableOfContents
datacite.description.TableOfContents

folder "rotated": nano-CT volume with gray value images folder "rotated segmented": correlated information of nano-CT and EDXS "particlewise.mha": raw data of particle-discrete information (without phase-specific information from EDXS)

Documentation of the data
datacite.description.TechnicalInfo

- tomographic sections as *.tif (16 bit) - raw data as *.mha (open with ImageJ or Python:MathPy) 3D measurement via X-ray nano-tomography (nano-CT) + correlative measurements with EDXS signal originating from FIB-SEM analysis

Countries to which the data refer
datacite.geolocation.iso3166

GERMANY

Description of the data
datacite.resourceType

Saxolite and Talcum are two materials with comparable X-ray attenuating properties and thus not to distinguish by direct comparison of image gray values.

Type of the data
datacite.resourceTypeGeneral

Image

Type of the data
datacite.resourceTypeGeneral

Dataset

Total size of the dataset
datacite.size

100692495277

Author
dc.contributor.author

Ditscherlein, Ralf

Upload date
dc.date.accessioned

2022-09-02T08:14:03Z

Upload date
dc.date.accessioned

2026-06-05T13:12:41Z

Publication date
dc.date.available

2022-09-02T08:14:03Z

Publication date
dc.date.available

2026-06-05T13:12:41Z

Data of data creation
dc.date.created

2022

Publication date
dc.date.issued

2022-09-02

Abstract of the dataset
dc.description.abstract

All 3 data sets are sub-volumes (Field of View approx. 65 µm) of a total sample of a particle mixture of talc and saxolite fixed in a matrix by means of epoxy resin and spacer particles (nanometre-sized carbon black particles, 150 nm equivalent spherical diameter). The primary analysis was carried out using nano-CT. The reconstructed result data are stored in the form of TIF files as sectional images (folder "rotated"). In addition, a correlation was carried out by means of EDXS analytics, the chemical information of which was used to train a segmentation algorithm. Since EDXS analysis requires a planar surface, the sample was further processed using FIB. The divergence of the ion beam produces a slight angular deviation from the perpendicular of the nano-CT volume, which necessitated a rotation of the initial volume data (--> "rotated"). The correlated result data of the particle-discrete phase information are also stored ("rotated segmented").

Public reference to this page
dc.identifier.uri

https://opara.zih.tu-dresden.de/handle/123456789/2544

Public reference to this page
dc.identifier.uri

https://doi.org/10.25532/OPARA-186

Publisher
dc.publisher

Technische Universität Bergakademie Freiberg

Licence
dc.rights

Attribution 4.0 International

URI of the licence text
dc.rights.uri

http://creativecommons.org/licenses/by/4.0/

Specification of the discipline(s)
dc.subject.classification

4::43::406

Specification of the discipline(s)
dc.subject.classification

4

Title of the dataset
dc.title

3 tomographic data sets of nano-CT measurements of a 30:70 vol-% mixture of talcum and saxolite

Research instruments
opara.descriptionInstrument

nano-CT (ZEISS, Xradia 810 ULTRA)

Research instruments
opara.descriptionInstrument

FIB-SEM + EDXS (FEI, Helios NanoLab 660, dual beam)

Underlying research object
opara.descriptionObject.Substance

micron-sized particle samples of talcum (Giessereitechnik Wystrach GmbH & Co. KG, Germany) and saxolite (type Saolith 2 extra, Erzgebirgische Kalkwerke GmbH GEOMIN, Germany), both 0.1 - 10 µm equivalent spherical diameter

Software
opara.descriptionSoftware.ResourceProcessing

Arivis Vision 4D (Version 3.5)

Software
opara.descriptionSoftware.ResourceProduction

ASTRA toolbox (Version 2.1.0)

Project abstract
opara.project.description

The 3D particle analysis offers the possibility to capture several particle characteristics simultaneously. However, when using X-ray tomography over several size scales (nano- and micro CT), it is not possible to derive quantitative information about the material composition of samples directly from the image grey values. Within the project, this is to be done by correlating the 3D volume with 2D elemental analysis (EDXS) utilizing a FIB-SEM workflow.

Project title
opara.project.title

Correlative X-ray tomography (Correlative Tomography)

Files

Original bundle

Now showing 1 - 4 of 4
Loading...
Thumbnail Image
Name:
contents.txt
Size:
1.08 MB
Format:
Plain Text
Loading...
Thumbnail Image
Name:
First_Volume.zip
Size:
28.99 GB
Format:
Description:
Loading...
Thumbnail Image
Name:
Second_Volume.zip
Size:
32.43 GB
Format:
Description:
Loading...
Thumbnail Image
Name:
Third_Volume.zip
Size:
32.36 GB
Format:
Description:
Attribution 4.0 International