X-ray tomography scan of a cubical-shaped lithium aluminate slag particle (4 mm)

datacite.FundingReference.funderName
datacite.FundingReference.funderName

Deutsche Forschungsgemeinschaft

Contributing person
datacite.contributor.ProjectLeader

Võ, Thu Trang (orcid: 0000-0003-1477-1095)

Contributing person
datacite.contributor.RightsHolder

Institute of Mechanical Process Engineering and Mineral Processing

Documentation of the data
datacite.description.TechnicalInfo

Data Processing: 1. non-local means denoising, 2. unsharp mask, 3. thresholding, 4. remove outliers, 5. skeletonizing (analyze connectivity), 6. local thickness (thickness of the microstructure), 7. directionality (analyze orientation)

Countries to which the data refer
datacite.geolocation.iso3166

GERMANY

Description of the data
datacite.resourceType

Screenshots of the measurement and reconstruction parameters, raw data set and processed data set for microstructure analysis. XCT scan of lithium aluminate slag (LiAlO2 as target phase) Raw data TIFF and processed TIFF in which just the target phase is shown in the binary stack. Measurement and reconstruction settings are included.

Type of the data
datacite.resourceTypeGeneral

Dataset

Type of the data
datacite.resourceTypeGeneral

Image

Total size of the dataset
datacite.size

1445289067

Author
dc.contributor.author

Vo, Thu Trang

Upload date
dc.date.accessioned

2023-09-11T12:28:43Z

Publication date
dc.date.available

2023-09-11T12:28:43Z

Publication date
dc.date.available

2026-06-11T15:50:07Z

Data of data creation
dc.date.created

2022-2023

Publication date
dc.date.issued

2023-09-11

Abstract of the dataset
dc.description.abstract

X-ray tomography scans of a cubical-shaped lithium aluminate slag. This folder is split into the raw data TIFF before image processing, and the processed TIFF. The latter shows a binary stack containing only the microstructure of the target material, in this case the lithium aluminate. Information about the measurement and reconstruction settings is included.

Public reference to this page
dc.identifier.uri

https://opara.zih.tu-dresden.de/handle/123456789/2686

Public reference to this page
dc.identifier.uri

https://doi.org/10.25532/OPARA-242

dc.language
dc.language

eng

Publisher
dc.publisher

Technische Universität Bergakademie Freiberg

Licence
dc.rights

Attribution 4.0 International

URI of the licence text
dc.rights.uri

http://creativecommons.org/licenses/by/4.0/

Specification of the discipline(s)
dc.subject.classification

4

Specification of the discipline(s)
dc.subject.classification

4::43::406

Specification of the discipline(s)
dc.subject.classification

3::34

Title of the dataset
dc.title

X-ray tomography scan of a cubical-shaped lithium aluminate slag particle (4 mm)

Research instruments
opara.descriptionInstrument

Zeiss Xradia 510 Versa

Underlying research object
opara.descriptionObject.PhysicalObject

Lithium aluminate containing slag (S2)

Underlying research object
opara.descriptionObject.PhysicalObject

Ltihium aluminate slag

Software
opara.descriptionSoftware.ResourceProcessing

FIJI (Version ImageJ 1.53b)

Project abstract
opara.project.description

The comminution of multiphase particles depends on several influencing variables, such as the microstructure. This is often described in terms of defects, interfaces and phases. XCT (X-ray Computed Tomography) is used to gain insight into the microstructure of slag particles. Lithium aluminate slag is used as the slag system, with the lithium aluminate as the target phase which needs to be liberated. A slag cube with an edge length of about 4 mm was measured with the XCT (Zeiss Xradia 510 Versa). A 3D representation of the target phase can be obtained by further image processing of the raw data set. The XCT raw data set and the binary data set for the target phase are provided. The measurement and reconstruction settings can also be found here. This supplements ar part of the publication: Utilizing X-Ray computed tomography for lithium slag: A guide to analyze microstructure and its potential influence on liberation.

Project title
opara.project.title

X-Ray tomography measurement of a cubical shaped lithium aluminate slag particle: Raw and processed data set and XCT information (DFG PP 2315 - C12)

Files

Original bundle

Now showing 1 - 5 of 5
Loading...
Thumbnail Image
Name:
TIFF.zip
Size:
1.32 GB
Format:
Description:
X-ray tomographic scan of a single cubical-shaped lithium aluminate slag particle (raw TIFF)
Loading...
Thumbnail Image
Name:
TIFF_processed.zip
Size:
28.02 MB
Format:
Description:
XCT scan of a single cubical-shaped lithium aluminate slag particle (image processed TIFF)
Loading...
Thumbnail Image
Name:
overview.JPG
Size:
491.14 KB
Format:
Joint Photographic Experts Group/JPEG File Interchange Format (JFIF)
Description:
Overview of the slag particle sample
Loading...
Thumbnail Image
Name:
parameter.JPG
Size:
259.06 KB
Format:
Joint Photographic Experts Group/JPEG File Interchange Format (JFIF)
Description:
XCT measurement and reconstruction settings of the slag particle sample
Loading...
Thumbnail Image
Name:
image_processing.txt
Size:
189 B
Format:
Plain Text
Description:
Image processing steps in Fiji (imageJ version 1.53b)
Attribution 4.0 International