IV curves obtained from thermionic emission tests with C12A7:e- thick film samples

datacite.FundingReference.funderName
datacite.FundingReference.funderName

Europäische Union

Contributing person
datacite.contributor.ProjectLeader

Tajmar, Martin (orcid: 0000-0002-7406-7588)

Documentation of the data
datacite.description.TechnicalInfo

Resource Type: Current Density measurements in dependence of temperature and extraction voltage of C12A7:e- composite thick film samples in high vacuum (base pressure: 5E-8 mbar/with argon gas as inert purge gas to prevent evaporationm of titanium: 1E-4 mbar) Data Acquisition: Thermionic emission current density measured with thermionic diode.

Description of the data
datacite.resourceType

Bulk and Coating Characterisation Thermionic Emission measurement data of thick film C12A7:e- paste (t=100 µm) on titanium substrates. Samples prepared by Fraunhofer IKTS. Tests conducted by Institute of Aerospace Engineering (TU Dresden).

Type of the data
datacite.resourceTypeGeneral

Dataset

Total size of the dataset
datacite.size

7533140

Author
dc.contributor.author

Wulfkühler, Jan-Philipp

Author
dc.contributor.author

Martin, Tajmar

Upload date
dc.date.accessioned

2022-11-22T10:19:11Z

Publication date
dc.date.available

2022-11-22T10:19:11Z

Publication date
dc.date.available

2026-06-10T15:44:00Z

Data of data creation
dc.date.created

2019 - 2022

Publication date
dc.date.issued

2022-11-22

Abstract of the dataset
dc.description.abstract

Thermionic emission current density measurement of C12A7:e- thick film samples. Samples prepared by Fraunhofer IKTS. Bulk coating: Proprietary composite with C12A7:e-. Thickness: 100 µm. Substrate: Titanium Measurement conducted by Institute of Aerospace Engineering of TU Dresden.

Public reference to this page
dc.identifier.uri

https://opara.zih.tu-dresden.de/handle/123456789/2619

Public reference to this page
dc.identifier.uri

https://doi.org/10.25532/OPARA-193

dc.language
dc.language

eng

Publisher
dc.publisher

Technische Universität Dresden

Licence
dc.rights

Attribution 4.0 International

URI of the licence text
dc.rights.uri

http://creativecommons.org/licenses/by/4.0/

Specification of the discipline(s)
dc.subject.classification

3::32

Specification of the discipline(s)
dc.subject.classification

4

Title of the dataset
dc.title

IV curves obtained from thermionic emission tests with C12A7:e- thick film samples

Underlying research object
opara.descriptionObject.PhysicalObject

C12A7:e- thick film samples. Coating: 10 x 10 mm² with 100 µm thickness Composition: Proprietary composite material based on C12A7:e- developed by Fraunhofer IKTS. Substrate: Pure titanium sheet, 20 x 20 mm²

Project abstract
opara.project.description

Goal: Development of a Deorbit Kit (DK) and related software based on Low Work function Tether (LWT) technology with TRL 4. Total Budget: 3M€ (Funded by the European Commission). Partners: UC3M, IKTS, UNIPD, TUD, SENER, and ATD. Potential impact: reversible and free of consumables in-space propulsion technology.

Project title
opara.project.title

Electrodynamic Tether Technology for Passive Consumable-less Deorbit Kit (E.T.PACK)

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
C12A7_DataManagementPlan_TUD.xlsx
Size:
7.18 MB
Format:
Microsoft Excel XML
Description: