Determination of the temperature development in the cryogenic range for determination of heat transfer coefficient

Contributing person
datacite.contributor.ProjectLeader

Brosius, Alexander (orcid: 0000-0002-9941-390X)

Description of the data
datacite.resourceType

Experimental setup and measured temperature time series in workpiece and tools for determination of heat transfer coefficient

Type of the data
datacite.resourceTypeGeneral

Dataset

Type of the data
datacite.resourceTypeGeneral

Image

Total size of the dataset
datacite.size

11601568

Author
dc.contributor.author

Tulke, Marc

Upload date
dc.date.accessioned

2023-04-18T11:57:09Z

Publication date
dc.date.available

2023-04-18T11:57:09Z

Publication date
dc.date.available

2026-06-10T15:42:43Z

Data of data creation
dc.date.created

2023

Publication date
dc.date.issued

2023-04-18

Abstract of the dataset
dc.description.abstract

Lightweight materials such as aluminum alloys have an important role to play in weight reduction. However, their limited formability at room temperature poses a major challenge and restricts their use. Significant improvements in formability can be achieved by heat-assisted forming processes. However, this improvement in formability is generally associated with a change in microstructure that leads to a reduction in strength. Alternatively, improved ductility and formability can be achieved at cryogenic temperatures without the disadvantages of warm forming processes. In this project, the focus is on developing a new process for forming aluminum alloys at cryogenic temperatures without active cooling. For this purpose, macro-structured tools are used to reduce the contact area between the tool and the blank. The aim is to minimize the heat flux to the blank to maintain low temperatures during forming. This is to take advantage of the improved formability of aluminum alloys at cryogenic temperatures and thus extend the process window for deep drawing of aluminum alloys. This data collection contains material characterization data required for numerical process modelling. The focus is on the characterization of thermal and mechanical properties at blank temperatures. The accuracy of a thermomechanical simulation depends on thermal parameters and the description of the heat transfer. The presented data contains an experimental setup and the measured temperature development in the workpiece and tools for determining heat transfer coefficient. Here the workpiece is made of AA6014 and the tools are made of 1.7225. The workpiece is cooled in liquid nitrogen before the tests, while the tools remain at room temperature. The temperature is continuously measured, while different amounts of contact pressure starting at 0.1 MPa up to 50 MPa are applied. The heat transfer coefficient can then be calculated for the different contact pressure. The heat transfer coefficient between workpiece and tools can be determined from the experimentally determined temperature time series. The challenge here is the continuous change of the workpiece temperature and that no equilibrium is achieved. Therefore, a computation method was developed using least square fitting between the model output and the measured temperature curves, with the heat transfer coefficient as the parameter to optimize. The code for the parameter identification is published on GitHub: https://github.com/tud-if-ff/CryoHTC. A detailed description of the experimental setup and the used model for determining the heat transfer coefficient is published in the upcoming participation at the International Conference for Technological Plasticity 2023, with the working title: "Contact conditions and temperature distribution during cryogenic deep drawing with macro-structured tools".

Public reference to this page
dc.identifier.uri

https://opara.zih.tu-dresden.de/handle/123456789/2627

Public reference to this page
dc.identifier.uri

https://doi.org/10.25532/OPARA-218

Publisher
dc.publisher

Technische Universität Dresden

Licence
dc.rights

Attribution-NonCommercial-ShareAlike 4.0 International

URI of the licence text
dc.rights.uri

http://creativecommons.org/licenses/by-nc-sa/4.0/

Specification of the discipline(s)
dc.subject.classification

4

Title of the dataset
dc.title

Determination of the temperature development in the cryogenic range for determination of heat transfer coefficient

Project abstract
opara.project.description

Lightweight materials such as aluminum alloys have an important role to play in weight reduction. However, their limited formability at room temperature poses a major challenge and restricts their use. Significant improvements in formability can be achieved by heat-assisted forming processes. However, this improvement in formability is generally associated with a change in microstructure that leads to a reduction in strength. Alternatively, improved ductility and formability can be achieved at cryogenic temperatures without the disadvantages of warm forming processes. In this project, the focus is on developing a new process for forming aluminum alloys at cryogenic temperatures without active cooling. For this purpose, macro-structured tools are used to reduce the contact area between the tool and the blank. The aim is to minimize the heat flux to the blank to maintain low temperatures during forming. This is to take advantage of the improved formability of aluminum alloys at cryogenic temperatures and thus extend the process window for deep drawing of aluminum alloys.

Project title
opara.project.title

Cryogenic forming of aluminium alloys with macro-structured tools

Files

Original bundle

Now showing 1 - 6 of 6
Loading...
Thumbnail Image
Name:
Temperature-development_0MPa.csv
Size:
2.88 MB
Format:
Comma-Separated Values
Description:
Temperature measurement for contact pressure of 0.1 MPa
Loading...
Thumbnail Image
Name:
Temperature-development_10MPa.csv
Size:
2.96 MB
Format:
Comma-Separated Values
Description:
Temperature measurement for contact pressure of 10 MPa
Loading...
Thumbnail Image
Name:
Temperature-development_30MPa.csv
Size:
2.17 MB
Format:
Comma-Separated Values
Description:
Temperature measurement for contact pressure of 30 MPa
Loading...
Thumbnail Image
Name:
Temperature-development_50MPa.csv
Size:
3 MB
Format:
Comma-Separated Values
Description:
Temperature measurement for contact pressure of 50 MPa
Loading...
Thumbnail Image
Name:
Experimental_setup.png
Size:
65.96 KB
Format:
Portable Network Graphics
Description:
Experimental setup for continuous temperature measurement
Loading...
Thumbnail Image
Name:
Readme.txt
Size:
821 B
Format:
Plain Text