Computed tomography data of different resolution of expanded polypropylene foams of different density

datacite.FundingReference.funderName
datacite.FundingReference.funderName

Deutsche Forschungsgemeinschaft

Contributing person
datacite.contributor.HostingInstitution

Institute of Lightweight Engineering and Polymer Technology - ILK

Contributing person
datacite.contributor.ProjectLeader

Gude, Maik (orcid: 0000-0003-1370-064X)

Contributing person
datacite.contributor.Researcher

Grüber, Bernd

Contributing person
datacite.contributor.Researcher

Müller-Pabel, Michael

Documentation of the data
datacite.description.TechnicalInfo

Resource Type: - *.pca- and *.pcr-files (readable by any editor) containing parameters for image aquisition and reconstruction for coarse scans (CS) - x-ray computed tomography data of the coarse scans (CS) in form of zip-files including *.vol-Files (raw pixels encoded as integers; volume generation using ROI_Size from *.pcr-file) - x-ray computed tomography data in form of txm-Files by Zeiss (ole-format, also readable by FIJI/ImageJ using XRM-Reader Plugin) - ROI-definitions (*.zip) from FIJI/ImageJ ROI-Manager plugin defining the reagions of interests used for segmentation and high resolution scans - volume image data of segmented cell walls in form of image stacks *.tif readable in FIJI/ImageJ Data Acquisition: The image acquisition is performed on two very different X-ray computed tomography systems. Scans of the whole specimens, further on referred to as \"coarse\" (CS) in the file names, were performed using a v|tome|x L 450 system from GE located at the Institute of Lightweight Engineering and Polymer Technology at TU Dresden with a microfocus tube of 300 kV maximum acceleration voltage and a wolfram target. After scanning, the CS data has been imported to VGStudio, cropped to the specimen volume and exported as image stack of the circular cross section with a plane resolution of 26 µm under preservation of 7 µm resolution in axial direction.\r\nAdditional scans of the identical specimens with a high resolution X-ray computed tomography system Zeiss Versa 520 were carried out at the Dresden Center for Nanoanalysis (DCN). The results are further on referred to as \"high resolution\" scans (HRS) in the file names. Due to technical and financial limitations, selected cylindrical regions of interest (ROI) with a diameter and height of approximately 1 mm of each sample were scanned. Data Processing: For analyzing the micro- and meso-structure of EPP bead foams Trainable WEKA Segmentation provided by the open source package FIJI is used. Three classes are defined: "cell walls", "cell volume" and "background". The classes are selected with the onboard selection tools of FIJI in one image of the individual image stacks, the classifier is subsequently trained and the resulting model is applied to the rest of the image stack gaining probability maps of the different classes. In a final step the probability maps are converted to segmented image stacks by the pixel wise allocation of the class of highest probability. The high resolution scans are segmented using the standard filter settings and for the coarse scans the most suitable results come from application of the training features Gaussian blur, Hessian, Membrane projections, Sobel Filter, Difference of gaussians and Neighbors. Further missegmentations of the class "background" are suppressed by filling the cylindrical specimen volume with the grey value of class "cell volume" consistently. Methods: The main image aquisition parameters for the coarse scans (CS, v|tome|x L 450) are: Acceleration voltage: 50 kV Beam current: 100 μA Focal spot: ≈7μm Number of projections: 720 Exposure time: 4000 ms The main image aquisition parameters for the high resolution scans (HRS, Zeiss Versa 520) are: Acceleration voltage: 30 kV Beam current: ≈ 67 μA Number of projections: 3201 Exposure time: ≈ 24.00 s

Description of the data
datacite.resourceType

Computed tomography data of different resolution of expanded polypropylene foams of different density Description: Bead foams with their hierarchical geometrical structure are a challenge in statistical reconstruction and finite element modelling. For the purpose of providing fundamental micro- and meso-structural descriptors of expanded polypropylene bead foams of different density, 3D-images from X-ray computed tomography (CT) are acquired. The data provided comprise reconstructed volume data as well as segmented data of three specimens of different density. Coarse scans of the specimen volume, definitions of certain regions of interests (ROI) as well as high resolution scans of the ROIs are included.

Type of the data
datacite.resourceTypeGeneral

Dataset

Type of the data
datacite.resourceTypeGeneral

Image

Total size of the dataset
datacite.size

29002136151

Author
dc.contributor.author

Preiß, Gina

Author
dc.contributor.author

Löffler, Markus

Author
dc.contributor.author

Koch, Ilja

Author
dc.contributor.author

Geske, Vinzenz

Author
dc.contributor.author

Danczak, Marek

Author
dc.contributor.author

Gude, Maik

Upload date
dc.date.accessioned

2022-12-13T08:07:10Z

Publication date
dc.date.available

2022-12-13T08:07:10Z

Publication date
dc.date.available

2026-06-10T15:43:50Z

Data of data creation
dc.date.created

2021-2022

Publication date
dc.date.issued

2022-12-13

Abstract of the dataset
dc.description.abstract

In this work, the morphology of three EPP bead foams with closed cells and different densities is studied using x-ray computed tomography. The specimens of 10 mm diameter and 10 mm length were cut from steam-chest-molded plates of 40 mm thickness. The plates are based on beads of different bulk densities (Neopolen (BASF) P92HD 105, 92HD 130, 92HD 180) and welded together in an Energy Foamer 5.0 of Kurtz Ersa using the crack-fill-method. The image acquisition is performed on two very different X-ray computed tomography systems. Scans of the whole specimens, further on referred to as "coarse", were performed using a v|tome|x L 450 system from GE located at the Institute of Lightweight Engineering and Polymer Technology at TU Dresden. Additional scans of certain regions of interest of the identical specimens with a high resolution X-ray computed tomography system Zeiss Versa 520 were carried out at the Dresden Center for Nanoanalysis (DCN). The results are further on referred to as "high resolution" scans. For analysing and statistical describing the micro- and meso-structure the cell walls are further on segmented from the different CT-volumes using WEKA-segmentation provided by the open-source package distribution FIJI. The provided data set enables the direct comparison of the results of different tomography setups at selected regions of interest and the deeper understanding of the multi-scale morphology of bead foams.

Public reference to this page
dc.identifier.uri

https://opara.zih.tu-dresden.de/handle/123456789/2624

Public reference to this page
dc.identifier.uri

https://doi.org/10.25532/OPARA-194

dc.language
dc.language

eng

Publisher
dc.publisher

Technische Universität Dresden

Licence
dc.rights

Attribution-NonCommercial-ShareAlike 4.0 International

URI of the licence text
dc.rights.uri

http://creativecommons.org/licenses/by-nc-sa/4.0/

Specification of the discipline(s)
dc.subject.classification

4::43::406

Specification of the discipline(s)
dc.subject.classification

4

Title of the dataset
dc.title

Computed tomography data of different resolution of expanded polypropylene foams of different density

Underlying research object
opara.descriptionObject.Substance

In this work, the morphology of three EPP bead foams with closed cells and different densities is studied using x-ray computed tomography. The specimens of 10 mm diameter and 10 mm length were cut from steam-chest-molded plates of 40 mm thickness. The plates are based on beads of different bulk densities (Neopolen (BASF) P92HD 105, 92HD 130, 92HD 180) and welded together in an Energy Foamer 5.0 of Kurtz Ersa using the crack-fill-method.

Software
opara.descriptionSoftware.ResourceProcessing

FIJI (Version 1.53v)

Project abstract
opara.project.description

Partikelschäume zeichnen sich aus durch eine einzigartige Kombination von geringer Dichte, hoher mechanischer Energieabsorption bei Druckbelastung, großer Gestaltungsfreiheit in der Formgebung sowie geringen Herstellungskosten. Sie sind damit für vielfältige Einsatzgebiete prädestiniert, zu denen derzeit u.a. Sportschuhe und sicherheitsrelevante Interieur-Bauteile von Fahrzeugen gehören. Durch Auswahl der Verarbeitungsparameter beim Schäumen können die Eigenschaften der Zellstruktur und damit das Verhalten der Formteile gezielt an die jeweilige Anwendung angepasst werden. Nach aktuellem Stand der Forschung bestehen jedoch signifikante Unsicherheiten bezüglich der Struktur-Eigenschafts-Beziehungen von Partikelschäumen. So sind zwar Berechnungsmethoden verfügbar, die zur Vorhersage des makroskopischen Werkstoffverhaltens bei beliebigen multiaxialen Belastungszuständen geeignet sind, jedoch werden dabei substantielle Vereinfachungen zugrunde gelegt, wie etwa die Vernachlässigung lokaler Spannungs- und Verzerrungsmaxima auf der Mesoebene des Schaums. So kommt es bei globaler Druckbelastung innerhalb der Zellstruktur lokal zu Biegung, Beulen oder Zugversagen. Das mechanische Verhalten wird zudem maßgeblich durch das eingeschlossene Zellgas und dessen Kompression beeinflusst. Werden die Formteile schwingend über einen längeren Zeitraum belastet, kommt es nach empirischen Erkenntnissen zu einem zyklischen Kriechen des Formteils. Sowohl die Interaktion zwischen Zellgas und Zellstruktur als auch die Phänomenologie des zyklischen Kriechens sind bisher nicht hinreichend aufgeklärt. Im Fokus des Vorhabens steht die experimentelle und numerische Untersuchung des mechanischen Verhaltens von Partikelschäumen unter quasi-statischer sowie zyklischer Belastung im Druckbereich. Mit Hilfe eines im Vorhaben zu entwickelnden Prüfstandes zur Durchführung von umgebungsdruckabhängigen Stauchungsversuchen sowie der Anwendung röntgentomografischer Analysen sollen die Wechselwirkungen zwischen Zellgas, Zellstruktur und Grundpolymer einerseits und den zeitabhängigen mechanischen Eigenschaften des Partikelschaums andererseits analysiert werden. Im Mittelpunkt stehen dabei die viskoelastischen Eigenschaften und das Kriechverhalten des Partikelschaums sowie die globalen und lokalen Spannungs-Stauchungs-Verläufe bei wiederholter Be- und Entlastung. Die Analyse der Zellmorphologie bildet die Grundlage für die numerische Simulation der Partikelschäume, wobei zunächst einzelne Be- und Entlastungsschritte unter Berücksichtigung der Zellstruktur, des Zellgases und der Viskoelastizität simuliert werden. Hierdurch sollen insbesondere inelastische Effekte und Instabilitäten auf lokaler Ebene detektiert und deren Auswirkung auf das globale Verhalten identifiziert werden. Die Arbeiten schaffen damit wichtige Grundlagen für ein verbessertes Materialverständnis, das für eine ressourceneffizientere und verlässlichere Auslegung von langzeitbeanspruchten Partikelschaumstrukturen notwendig ist.

Project title
opara.project.title

Zyklisch-dynamische Eigenschaften von Partikelschäumen (Hysteresis)

Files

Original bundle

Now showing 1 - 20 of 28
Loading...
Thumbnail Image
Name:
EPP120_CS.pca
Size:
2.7 KB
Format:
Unknown data format
Description:
Image aquision parameter file, specimen EPP120, coarse scan
Loading...
Thumbnail Image
Name:
EPP120_CS.pcr
Size:
956 B
Format:
Unknown data format
Description:
Image reconstruction parameter file, specimen EPP120, coarse scan
Loading...
Thumbnail Image
Name:
EPP120_CS_ROI_1_ROIdefinition.zip
Size:
41.51 KB
Format:
Description:
FIJI ROI-Manager definition of ROI 1, specimen EPP120, coarse scan
Loading...
Thumbnail Image
Name:
EPP120_CS_ROI_1_segmented.tif
Size:
242.61 KB
Format:
Tag Image File Format
Description:
segmented volume, ROI 1, specimen EPP120, coarse scan
Loading...
Thumbnail Image
Name:
EPP120_CS_ROI_2_ROIdefinition.zip
Size:
41.68 KB
Format:
Description:
FIJI ROI-Manager definition of ROI 2, specimen EPP120, coarse scan
Loading...
Thumbnail Image
Name:
EPP120_CS_ROI_2_segmented.tif
Size:
244.3 KB
Format:
Tag Image File Format
Description:
segmented volume, ROI 2, specimen EPP120, coarse scan
Loading...
Thumbnail Image
Name:
EPP180_CS.pca
Size:
2.67 KB
Format:
Unknown data format
Description:
Image aquision parameter file, specimen EPP180, coarse scan
Loading...
Thumbnail Image
Name:
EPP180_CS.pcr
Size:
956 B
Format:
Unknown data format
Description:
Image reconstruction parameter file, specimen EPP180, coarse scan
Loading...
Thumbnail Image
Name:
EPP180_CS_ROI_1_ROIdefinition.zip
Size:
39.5 KB
Format:
Description:
FIJI ROI-Manager definition of ROI 1, specimen EPP180, coarse scan
Loading...
Thumbnail Image
Name:
EPP180_CS_ROI_1_segmented.tif
Size:
235.66 KB
Format:
Tag Image File Format
Description:
segmented volume, ROI 1, specimen EPP180, coarse scan
Loading...
Thumbnail Image
Name:
EPP180_CS_segmented.tif
Size:
387.46 MB
Format:
Tag Image File Format
Description:
segmented volume, specimen EPP180, coarse scan
Loading...
Thumbnail Image
Name:
EPP120_CS_segmented.tif
Size:
402.76 MB
Format:
Tag Image File Format
Description:
segmented volume, specimen EPP120, coarse scan
Loading...
Thumbnail Image
Name:
EPP120_HRS_ROI_1_segmented.tif
Size:
948.01 MB
Format:
Tag Image File Format
Description:
segmented volume, ROI 1, specimen EPP120, high resolution scan
Loading...
Thumbnail Image
Name:
EPP120_HRS_ROI_2_segmented.tif
Size:
948.07 MB
Format:
Tag Image File Format
Description:
segmented volume, ROI 2, specimen EPP120, high resolution scan
Loading...
Thumbnail Image
Name:
EPP180_HRS_ROI_1_segmented.tif
Size:
937.56 MB
Format:
Tag Image File Format
Description:
segmented volume, ROI 1, specimen EPP180, high resolution scan
Loading...
Thumbnail Image
Name:
EPP240_CS_ROI_1_ROIdefinition.zip
Size:
37.38 KB
Format:
Description:
FIJI ROI-Manager definition of ROI 1, specimen EPP240, coarse scan
Loading...
Thumbnail Image
Name:
EPP240_CS_ROI_1_segmented.tif
Size:
218.7 KB
Format:
Tag Image File Format
Description:
segmented volume, ROI 1, specimen EPP240, coarse scan
Loading...
Thumbnail Image
Name:
EPP240_CS_segmented.tif
Size:
280.62 MB
Format:
Tag Image File Format
Description:
segmented volume, specimen EPP240, coarse scan
Loading...
Thumbnail Image
Name:
EPP240_HRS_ROI_1_segmented.tif
Size:
941.38 MB
Format:
Tag Image File Format
Description:
segmented volume, ROI 1, specimen EPP240, high resolution scan
Loading...
Thumbnail Image
Name:
EPP240_CS.pca
Size:
2.67 KB
Format:
Unknown data format
Description:
Image aquision parameter file, specimen EPP240, coarse scan