Multi-Scale Tomographic Analysis for Micron-Sized Particulate Samples - RAW Data
datacite.FundingReference.funderName | Europäische Union | |
Contributing person | Ditscherlein, Ralf (orcid: 0000-0003-0233-4218) | |
Contributing person | de Langlard, Mathieu | |
Contributing person | Furat, Orkun | |
Contributing person | Martins de Souza e Silva, Juliana | |
Contributing person | Sygusch, Johanna | |
Contributing person | Leißner, Thomas | |
Contributing person | Peuker, Urs A. | |
Contributing person | Schmidt, Volker | |
Contributing person | Rudolph, Martin | |
datacite.description.TableOfContents | - 1 LARGE scan (overall sample), split into I, II, III, IV, V - 3 SUB-Samples medium resolution (ZEISS VERSA510) - same 3 SUB-Samples high resolution (ZEISS ULTRA810) | |
Documentation of the data | Data Processing: reconstruction with ZEISS Reconstructor, filtered back projection, Smoothing 0.1 (Gauß), Beam Hardening Correction 0.05 (only for polychromatic scans --> 810 ULTRA) REMARK: - 50 slices at top and bottom of the low-res and medium-res scans are distorted due to the cone-beam artefact. Typically they will be removed from the analyzed volume. - high-resolution scans are with artefacts due to the interior scanning of the sample. Parts outside the FOV are influencing the reconstructed volume. | |
Description of the data | Glass Particles(Glass) including - 1 LARGE sample with low-resolution data (micro-CT, VERSA510) - splitted in I, II, III, IV, V - 3 SUB-Samples MEDIUM-resolution (cutted down from above LARGE sample, scanned with micro-CT, ZEISS VERSA510) - 3 SUB-Samples HIGH-resolution (same as MEDIUM, scanned with nano-CT, ZEISS ULTRA810) scan with micro-CT and nano-CT | |
Type of the data | Image | |
Total size of the dataset | 13616949066 | |
Author | Ditscherlein, Ralf | |
Author | Martins de Souza e Silva, Juliana | |
Upload date | 2020-01-08T09:31:53Z | |
Upload date | 2026-05-20T14:13:20Z | |
Publication date | 2020-01-08T09:31:53Z | |
Publication date | 2026-05-20T14:13:20Z | |
Data of data creation | 2019 | |
Publication date | 2019 | |
Abstract of the dataset | This repository includes the reconstructed TIFF-files from multiple scale tomographic analysis of particles in an embedding matrix (overall volume and 3 sub-volumes in 2 different magnification steps): LARGE (low-resolution) (due to filesize partioned in part I, II, III, IV and V) 1 large volume of particle mixture (50/50) of spheres (0.2 - 2 µm) and fibres (diameter: 10 µm length: 100 - 1000 µm) embedded in a matrix (wax, 15 vol-%). The large volume was extracted with an automated syringe into a small polymeric tube (diameter: 1.8 mm) and shock frozen. After that the sample was mounted on top of a needle pin and scanned with a micro-CT (ZEISS Versa510) at 80 keV, 7 W, low energy filter LE4, exposure time 2 s, optical magn. 4x, 3201 projections, 360°, Binning 2, Voxelsize 1.5 µm SubSample - MEDIUM (medium-resolution) (SubSample 1, 2, 3) After the scan, the LARGE volume was cutted in small disks and cutted a second time in little bars. Again, mounted on top of a needle pin and scanned with same parameters, BUT with 40x optical magnification and 25 s exposure time to go down to a system limit of 0.3 µm Voxelsize (again with ZEISS VERSA510). This was done 3 times in different heights of the LARGE volume SubSample - HIGH (high-resolution) (SubSample 1, 2, 3) After that, all SubSamples were scanned again with a nano-CT (ZEISS ULTRA810) at 5.4 keV, 60 s exposure time, 901 projections, 180°, Binning 1 to reach Voxelsize of 0.064 µm | |
Public reference to this page | https://opara.zih.tu-dresden.de/handle/123456789/2382 | |
Public reference to this page | https://doi.org/10.25532/OPARA-50 | |
dc.language | eng | |
Publisher | Technische Universität Bergakademie Freiberg | |
Licence | Attribution 4.0 International | |
URI of the licence text | http://creativecommons.org/licenses/by/4.0/ | |
Specification of the discipline(s) | 4 | |
Title of the dataset | Multi-Scale Tomographic Analysis for Micron-Sized Particulate Samples - RAW Data | |
Research instruments | Xradia 810 ULTRA | |
Research instruments | Xradia 510 VERSA | |
Underlying research object | volume of particle mixture (50/50) of spheres (0.2 - 2 µm) and fibres (diameter: 10 µm length: 100 - 1000 µm) embedded in a matrix (wax, 15 vol-%). The large volume was extracted with an automated syringe into a small polymeric tube (diameter: 1.8 mm) and shock frozen. After that the sample was mounted on top of a needle pin. | |
Software | Scout&Scan Reconstructor (Version 11.1.8043) |
Files
Original bundle
- Name:
- SubSample1_MidResolution.zip
- Size:
- 1.05 GB
- Format:
- Description:
- SubSample 1 MediumResolution
- Name:
- SubSample1_HighResolution.zip
- Size:
- 1.22 GB
- Format:
- Description:
- SubSample 1 HighResolution
- Name:
- SubSample2_MidResolution.zip
- Size:
- 1.04 GB
- Format:
- Description:
- SubSample 2 MediumResolution
- Name:
- SubSample2_HighResolution.zip
- Size:
- 1.3 GB
- Format:
- Description:
- SubSample 2 HighResolution
- Name:
- SubSample3_MidResolution.zip
- Size:
- 1.04 GB
- Format:
- Description:
- SubSample 3 MediumResolution
- Name:
- SubSample3_HighResolution.zip
- Size:
- 1.26 GB
- Format:
- Description:
- SubSample 3 HighResolution
Collections