PGT Prompt Gamma Timing PETsys data for publication at IKTP (PGT)

Contributing person
datacite.contributor.ContactPerson

Olga Novgorodova

Countries to which the data refer
datacite.geolocation.iso3166

GERMANY

References to related material
datacite.relatedItem.IsPublishedIn

https://iopscience.iop.org/article/10.1088/1748-0221/19/02/P02030

Description of the data
datacite.resourceType

Pictures ROOT files Scripts for analysis

Type of the data
datacite.resourceTypeGeneral

Collection

Total size of the dataset
datacite.size

13440967542

Author
dc.contributor.author

Novgorodova, Olga

Author
dc.contributor.author

Straessner, Arno

Author
dc.contributor.author

Hentges, Rainer

Author
dc.contributor.author

Glatte, Andreas

Author
dc.contributor.author

Lutz, Benjamin

Author
dc.contributor.author

Roemer, Katja

Author
dc.contributor.author

Teichmann, Thobias

Author
dc.contributor.author

Koegler, Toni

Upload date
dc.date.accessioned

2024-05-14T08:06:32Z

Publication date
dc.date.available

2024-05-14T08:06:32Z

Data of data creation
dc.date.created

2023

Publication date
dc.date.issued

2024-05-14

Abstract of the dataset
dc.description.abstract

Proton therapy requires range verification in order to exploit its full potential. One of the most promising approaches is to monitor prompt gamma-rays produced by nuclear interactions of the therapeutic particles in the patient tissues. In our paper, we test PETsys electronics with a detector with a wide energy range from 100 keV to 15 MeV. We tested what time resolution we could achieve as a high time resolution is required to achieve millimetric precision in the proton range. PETsys should survive high count rates and the fraction of pile-up events should be low or separatable. We are investigating a full acceptance approach with increased granularity in order to reduce the size of the scintillators and consequently the count rate per channel. Ideally, we want to stack the scintillators in matrices that require suitable multi-channel photo-multipliers and a fitting acquisition system. Here, we present two geometries of CeBr3 crystals 5 × 5 × 20 mm3 and 10 × 10 × 30 mm3, together with modern silicon photo-multipliers (SiPM) adapted to work with the PETsys TOFPET2 ASIC. The TOFPET2 ASIC was developed for Time-of-Flight Positron Emission Tomography (TOF-PET) applications. Here are our data measured for the publication for time resolution and coincidence time resolution, energy resolution with AmBe source, and dead time studies.

Public reference to this page
dc.identifier.uri

https://opara.zih.tu-dresden.de//handle/123456789/597

Public reference to this page
dc.identifier.uri

https://doi.org/10.25532/OPARA-461

Publisher
dc.publisher

Technische Universität Dresden

Licence
dc.rights

Attribution-NonCommercial-NoDerivatives 4.0 Internationalen

URI of the licence text
dc.rights.uri

http://creativecommons.org/licenses/by-nc-nd/4.0/

Specification of the discipline(s)
dc.subject.classification

3

Title of the dataset
dc.title

PGT Prompt Gamma Timing PETsys data for publication at IKTP (PGT)

Research instruments
opara.descriptionInstrument

PETsys Electronics Evaluation Kit, PMT, CAEN ADC v1730

Software
opara.descriptionSoftware.Other

own code C++

Project abstract
opara.project.description

Proton therapy requires range verification in order to exploit its full potential. One of the most promising approaches is to monitor prompt gamma-rays produced by nuclear interactions of the therapeutic particles in the patient tissues. In our paper, we test PETsys electronics with a detector with a wide energy range from 100 keV to 15 MeV. We tested what time resolution we could achieve as a high time resolution is required to achieve millimetric precision in the proton range. PETsys should survive high count rates and the fraction of pile-up events should be low or separatable. We are investigating a full acceptance approach with increased granularity in order to reduce the size of the scintillators and consequently the count rate per channel. Ideally, we want to stack the scintillators in matrices that require suitable multi-channel photo-multipliers and a fitting acquisition system. Here, we present two geometries of CeBr3 crystals 5 × 5 × 20 mm3 and 10 × 10 × 30 mm3, together with modern silicon photo-multipliers (SiPM) adapted to work with the PETsys TOFPET2 ASIC. The TOFPET2 ASIC was developed for Time-of-Flight Positron Emission Tomography (TOF-PET) applications. Here are our data measured for the publication for time resolution and coincidence time resolution, energy resolution with AmBe source, and dead time studies.

Public project website(s)
opara.project.publicReference

https://tu-dresden.de/mn/physik/iktp/arbeitsgruppen/experimentelle-teilchenphysik

Project title
opara.project.title

PGT Prompt Gamma Timing PETsys data for publication at IKTP (PGT)
Files
Original bundle
Now showing 1 - 20 of 21
Loading...
Thumbnail Image
Name:
Figure1.zip
Size:
591.44 KB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure2.zip
Size:
2.05 MB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure3.zip
Size:
9.7 MB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure4.zip
Size:
40.51 KB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure5.zip
Size:
35.54 KB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure6.zip
Size:
70.14 KB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure7.zip
Size:
4.59 MB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure8.zip
Size:
67.74 MB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure9.zip
Size:
5.1 MB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure10.zip
Size:
5.23 MB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure11.zip
Size:
29.43 MB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure12.zip
Size:
49.79 MB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure13.zip
Size:
249.26 KB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure14.zip
Size:
466.37 MB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure15.zip
Size:
21.51 KB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure16.zip
Size:
4 GB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure17.zip
Size:
35.46 KB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
Figure18.zip
Size:
4 GB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
steerFiles.tar.xz
Size:
5.29 KB
Format:
Unknown data format
Description:
Loading...
Thumbnail Image
Name:
README_Jinst_article.txt
Size:
28.79 KB
Format:
Plain Text
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
4.66 KB
Format:
Item-specific license agreed to upon submission
Description:
Attribution-NonCommercial-NoDerivatives 4.0 International