The OPARA service was recently upgraded to a new technical platform. You are visiting the outdated OPARA website. Please use https://opara.zih.tu-dresden.de/ for new data submissions. Previously stored data will be migrated in near future and then the old version of OPARA will finally be shut down. Existing DOIs for data publications remain valid.

Show simple item record

Metadata

Other contributing persons, institutions or organisationsGolde, Jonas - Arbeitsbereich Medizinische Physik und Biomedizinische Technik - ProjectLeader
Person(s) who is (are) responsible for the content of the research dataGrundmann, Julia
Used research instruments or devicesSCANCO vivaCT 40, SCANCO Medical AG, Brüttisellen, Switzerland
Research objectsTissue: teeth with occlusal caries
AbstractThis dataset contains the X-ray micro-computed tomography (µCT) volumes of the examined teeth as a 3D reference for all subsequent examinations. The µCT volumes were acquired on the intact, non-embedded teeth using a µCT specimen scanner (SCANCO vivaCT 40, SCANCO Medical AG, Brüttisellen, Switzerland) at the Bone Lab Dresden. All µCT scans were recorded with the following parameters: voltage: 70 kV, exposure time: 0.35 s, current: 0.114 mAs. The voxel size is 10.5 µm x 10.5 µm x 10.5 µm.
Additional keywordsX-ray micro-computed tomography
Languagedeu
Year or period of data production2021
Publication year2023
PublisherTechnische Universität Dresden
Content of the research dataDataset: uCT datasets
Holder of usage rightsTechnische Universität Dresden
Usage rights of the dataCC-BY-4.0
SoftwareResource Viewing: MATLAB (ImageJ)
Discipline(s)Engineeringde
Discipline(s)Medicinede
Discipline(s)Physicsde
Title of the datasetX-ray micro-computed tomography (µCT) volumes of carious teeth in vitro


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

  • uCT datasets [1]Open Access Icon
    This dataset contains the X-ray micro-computed tomography (µCT) volumes of the examined teeth as a 3D reference for all subsequent examinations. The µCT volumes were acquired on the intact, non-embedded teeth using a µCT specimen scanner (SCANCO vivaCT 40, SCANCO Medical AG, Brüttisellen, Switzerland) at the Bone Lab Dresden. All µCT scans were recorded with the following parameters: voltage: 70 kV, exposure time: 0.35 s, current: 0.114 mAs. The voxel size is 10.5 µm x 10.5 µm x 10.5 µm.

Show simple item record